PEROLO MEGA SUPERVENTIX SRV 2.5″ BSP DN65, 2.0 bar / 0.21 bar Vacuum

ISO Tank safety relief valve, MEGA SUPERVENTIX from PEROLO, protecting against both overpressure and vacuum in a single valve. DN65, 2½” BSP thread, set at Pressure 200 kPa (2.00 Bar) and Vacuum 21 kPa (0.21 Bar). Stainless Steel 316 / 1.4408 valve body, only 3 kg, compact with high flow.

Available as MX65F (standard) and MP65F (PED 2014/68/EU), compliant with ADR, IMDG, RID and ISO 4126-1 §7.3. Suited to ISO Tank Containers, Road Tankers, Rail Tanks and IBCs.

Complete genuine spare parts: O-ring Kit, Vacuum Spring Set, Setting Gasket, Flame Proof Gauze and Weld-in Flange. Ask Gavan Asia for prices and stock.

Open Monday to Saturday, 08:00 to 17:00

Description

MEGA SUPERVENTIX SRV 2.5″ BSP, Pressure 200 kPa / Vacuum 21 kPa, Pressure and Vacuum Safety Relief Valve ISO Tank safety relief valve for pressure and vacuum, DN65, for liquid transport tanks

Description

The MEGA SUPERVENTIX SRV 2.5″ BSP ISO Tank safety relief valve is a Pressure and Vacuum Safety Relief Valve made by PEROLO in France. It is available as MX65F (standard) and MP65F (PED) to protect tanks from overpressure and excessive vacuum.

The valve has a 2½ inch (DN65) bore and connects to the tank with a 2½” BSP thread, with relief settings of:

  • Pressure Setting: 200 kPa or 2.00 Bar
  • Vacuum Setting: 21 kPa or 0.21 Bar

When tank pressure reaches 2.00 Bar, the valve opens automatically to release gas or vapour. In the other direction, when negative pressure reaches 0.21 Bar, the Vacuum Relief opens to let air into the tank and balance it, reducing the risk of the tank deforming or collapsing.

MEGA SUPERVENTIX is compact but delivers high flow performance, suited to ISO Tank Containers, Road Tankers, Rail Tanks, IBCs and static pressure tanks.

How this ISO Tank safety relief valve works

Overpressure relief

The internal spring set holds the Pressure Plate closed. When tank pressure reaches the Set Pressure, it overcomes the spring force and the valve plate lifts to open the relief path. The spring then pushes the plate closed again when pressure balances.

If pressure rises quickly, the Pressure Plate can travel about 23 mm to increase the relief area and handle high flow.

Vacuum protection

When tank pressure drops to 0.21 Bar, the Vacuum Poppet opens to let air into the tank, balancing the pressure inside and outside. When pressure returns to normal, the Vacuum Poppet closes again automatically.

Technical data

  • Manufacturer: PEROLO (France)
  • Standard model: MX65F | PED model: MP65F
  • Nominal Diameter: DN65 or 2½ inch
  • Body Connection: 2½” BSP Threaded
  • Pressure Setting: 200 kPa / 2.00 Bar
  • Vacuum Setting: 21 kPa / 0.21 Bar / 210 mBar
  • Weight: 3 kg
  • Valve body material: Stainless Steel 316 / 1.4408
  • Setting Seal: FEP or PFA/Silicone depending on model | O-ring: FEP/Silicone
  • Working Temperature: -50°C to +190°C (temperature range may vary with seal material) | HT model up to +250°C
  • Model Pressure Setting range: 0.5 to 7.3 Bar | Vacuum Setting range: 50 to 410 mBar
  • Flow Measurement Condition: 101.3 kPa at 15°C | Flow reduction with Gauze fitted: less than 3%

All data per the manufacturer's Specification Sheet

Note on the 200 kPa Pressure Setting

2.00 Bar is within the MEGA SUPERVENTIX pressure setting range, but the standard Spring Sets in the Maintenance document come in 4 values: 2.18 / 3.30 / 3.75 / 4.40 Bar. The 2.00 Bar value is an Other on Request setting on the Codification page.

So before listing or quoting, always check the Nameplate on the valve, Full Part Number, Serial Number, Certificate and Pressure Test Report. Do not automatically substitute a 2.18 Bar Spring Set for the 2.00 Bar model, because the relief settings are not the same.

The Full Part Number also depends on other options such as Setting Seal, Flame Proof Gauze, Setting Gasket type, Vacuum Test Button and Halar Coating, so do not derive the code from the Pressure and Vacuum values alone.

Standards and certification

MEGA SUPERVENTIX is designed to comply with ADR, IMDG, RID and ISO 4126-1 §7.3, with Design Approval from DNV and RMR.

Model MP65F is certified to PED 2014/68/EU (Category IV, Module H1, Fluid Group 1, Notified Body: DNV) and covers Set Pressures up to 4.4 Bar, so 2.00 Bar is within range. Confirm that the actual product is an MP65F with a Certificate matching the Serial Number.

Key product features

  • Protects against both overpressure and vacuum in a single valve
  • Set at Pressure 200 kPa (2.00 Bar) and Vacuum 21 kPa (0.21 Bar)
  • 2½” BSP threaded connection, compact design, only 3 kg
  • Handles high relief flow rates
  • Available as MX65F (standard) and MP65F (PED)
  • Temperature range -50°C to +190°C, HT model up to +250°C
  • Optional Flame Proof Gauze, Bursting Disc and Pressure Gauge
  • Seal, Vacuum Kit and Spring Set spare parts sold separately

Suitable applications

Suited to ISO Tank Containers, Road Tankers, Rail Tank Cars, IBCs and Static Pressure Tanks, including tanks carrying liquid chemicals and liquid food products that need protection from both overpressure and negative pressure.

Before use, check that the Set Pressure matches the tank MAWP and that the valve, seal and product carried are compatible.

Basic installation steps

  1. Check that the Pressure and Vacuum Settings on the Nameplate suit the tank MAWP.
  2. Check Material Compatibility with the product carried.
  3. Install where gas or liquid from the valve will not spray towards operators.
  4. Remove the temporary Protective Cap and Gauze before assembly.
  5. Clean the thread, flange and Setting Gasket.
  6. Screw the valve in by hand with the gasket, then tighten with a C-Spanner to the Torque for the gasket material.
  7. Check the Wire Weld Seal and test for leaks after fitting.

Tightening torque by Setting Gasket type

  • Perbunan/PTFE: 80 N·m ±5 N·m
  • Composite/PTFE: 230 N·m ±5 N·m
  • PTFE: 240 N·m ±5 N·m
  • With a Bursting Disc and Adaptor Flange fitted: tighten the 6 M10 screws to 30 N·m ±5 N·m

Installation equipment and accessories

  • Weld-in Flange (12 91 14 00 00): Ext Ø 127 mm / Int Ø 76 mm / thickness 25 mm / 316L / 6 × M10 on PCD105
  • Recess Flange (12 92 14 00 00): Ext Ø 166 mm / Int Ø 76 mm / thickness 22 to 61 mm / 316L / 6 × M10 on PCD105
  • Seal: 11 10 01 60 00 | Screw Kit: 12 12 60 91 00
  • Bursting Disc Adaptor: 11 91 15 00 01 | Pressure Gauge: 70 18 06 00 95
  • Flame Proof Gauze Kit, Vacuum Test Button and Bursting Disc Assembly

Related parts

Pressure and Vacuum Seals

  • Pressure O-ring FEP/Silicone: 11 10 01 99 05 | set of 10: 11 10 01 99 06
  • Pressure & Vacuum O-ring Kit: 11 10 01 91 00 | Vacuum O-ring set of 10: 11 10 17 99 00

Standard Spring Sets per the manufacturer's documents

  • Spring Set 2.18 Bar: 11 10 01 95 00
  • Spring Set 3.30 Bar: 12 12 84 90 00
  • Spring Set 3.75 Bar: 11 10 01 96 00
  • Spring Set 4.40 Bar: 11 10 01 97 00
  • Spring Set Vacuum 0.21 Bar: 11 10 01 98 00

Other parts

  • Pressure/Vacuum Plate: 11 10 01 99 00 | Vacuum Poppet: 11 10 01 99 02 | Vacuum Set Kit: 11 10 01 99 08
  • Flame Proof Gauze Kit: 11 10 01 50 91
  • Composite/PTFE Gasket: 12 91 31 91 01 | Perbunan/PTFE Gasket: 11 10 01 93 00

For the 2.00 Bar Pressure Spring, confirm the Part Number with PEROLO or from the valve Certificate, as it is not in the standard Spring Set list.

Maintenance

The manufacturer recommends removing the valve for inspection in a Workshop about every 2 years, by specialists with a Test Rig for Safety Relief Valves only.

After replacing seals or the Spring Set, test the opening point at 2.00 Bar and Vacuum opening at 0.21 Bar with a Class 0.5 Manometer, then seal the Cap with Stainless Steel Wire. Only PEROLO parts should be used.

Precautions

  • Make sure the tank is not under pressure before removing the valve.
  • Do not remove the Cover while the Spring Set is still loaded. The Spring Load is between 100 and 400 daN and can fly out violently.
  • Do not adjust the Set Pressure without a Test Rig, and do not remove the Wire Weld Seal before the inspection interval.
  • Do not use a 2.18 Bar Spring Set in place of 2.00 Bar without certification.
  • Do not block the relief outlet, and check that the Flame Proof Gauze is not clogged.
  • Check Chemical Compatibility and that the settings match the Certificate before use.
  • The manufacturer states that the warranty ends immediately if non OEM parts are fitted.

Order the MEGA SUPERVENTIX SRV 2.5″ ISO Tank safety relief valve

Gavan Asia supplies the genuine PEROLO ISO Tank safety relief valve, DN65, BSP, set at Pressure 200 kPa and Vacuum 21 kPa, with the full set of parts: Vacuum Spring, O-ring Kit, Flame Proof Gauze, Setting Gasket, Weld-in Flange and Bursting Disc Assembly.

Before ordering, please send the Full Part Number, Serial Number, Certificate, Pressure/Vacuum Setting, PED Requirement and Setting Gasket type so we can confirm the model and the 2.00 Bar Pressure Spring. For prices and stock, contact Gavan Asia today.

Brand

Perolo

Model code

MX65F and MP65F (PED)

Type

Safety relief valve for ISO tanks, BSP threaded

Size

DN65 (2.5 inch)

Set Pressure

2.0 Bar g (200 kPa)

Vacuum Setting

0.21 Bar (21 kPa)

Connection

2½″ BSP thread

Body material

Stainless Steel 316 / 1.4408

Operating temperature

-50°C up to +190°C

Weight

3 kg